Products

ZVF600-G Series IP54 General Inverter

The ZVF600-G series IP54 general inverter, independently developed for high-protection pump applications, features a dustproof and water-splash resistant enclosure. It offers compatibility with various water pump motor junction boxes, supports multiple sensor signal types, and delivers simple operation, high reliability, and low noise. Capable of both standalone pump control and multi-unit networked operation.

PRODUCT DESCRIPTION

Main Features

ZVF600-G series IP54 general inverter is the company’s own research and development of high degree protection pump inverter, the shell is dustproof and splash water, can be installed different brand water pump motor junction box. Adapt to a variety of sensor signals, simple operation, high reliability, low noise, can be individually controlled a pump and can also be more on-line operation.

◆ high protection IP54 , all-round anti-corrosion anti-splash water

◆ High performance V / F and vector control

◆ Professional heat-resistant design, small power, without fan can be more reliable

◆ Directly installed on the motor, no need for the cabinet, simple and convenient to operate .

◆The function and software is same as ZVF300H series. can be used for water supply system and general purpose .

 

Demonstration of the Model

Specification

Inverter Outline& Mounting Dimension (Unit:mm)

 

 

ZVF600 IP54 Inverter Model Selection

 

Inverter Model Voltage (V) Power  (kW) Current (A) Dimension (mm) Figure
H H1 W W1 D d
ZVF600-G0R7S2M 220V 0.75 4.5 193 170 150 140 131 4.5 Fig.1
ZVF600-G1R5S2M 1.5 7.0
ZVF600-G2R2S2M 2.2 10
ZVF600-G3R7S2M 3.7 16 228 205 150 140 131 4.5 Fig.2
ZVF600-G0R7T4M 380V 0.75 2.5 193 170 150 140 131 4.5 Fig.1
ZVF600-G1R5T4M 1.5 3.7
ZVF600-G2R2T4M 2.2 5.0
ZVF600-G3R0T4M 3 6.8
ZVF600-G4R0T4M 4 9.0 228 205 150 140 131 4.5 Fig.2
ZVF600-G5R5T4M 5.5 13
ZVF600-G7R5T4M 7.5 17
Technical Indications
Item Item description
Input Rated voltage& Frequency Single /Three phase 220VAC . Three phase 380V.50Hz/60Hz
Allowable Voltage range Voltage fluctuate range:-20%~+20%

Voltage unbalance rate:<3%;Frequency fluctuation:≤5%

Output Rated voltage three phase 0~  input AC voltage
Frequency 0.00~600.00Hz
Basic Function Frequency accuracy Digital setting::Max. Frequency×±0.01%

Analog setting:Max. Frequency×±0.2%

Frequency resolution Digital setting :0.01HZ;

Analog setting :Max. Frequency x0.1%.

Starting frequency 0.00~50.00Hz
Acceleration/deceleration

time

0.1~3600 can be set in sequence .
Carrier frequency 1.0~15.0KHz
V/F curve 1:linear curve;2:quadratic;3:user defined V/F curve
Automatic energy-saving operation Auto optimize V/F curve according to the load changes to realize the energy saving operation .
Built-in PID This can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control  .
Operating command Operation panel control ,external terminal control and COM control
Frequency setting Keypad potentiometer setting , operation panel▲▼setting,. analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on.
Input Signal Forward/Reverse signal、multi-speed signal 、 fault signal 、

reset signal etc

Output Signal Programmable relay
Other Function Over voltage alarm 、Rotation speed tracking、 Momentary power loss restart 、Frequency upper/lower limiting、 Acceleration/ Deceleration mode can be adjusted 、Multi-speed/ program running、Fault auto reset、RS485 serial communication .
Protection Function Input phase loss protection、 Over current protection 、Overload protection、 Over voltage protection 、Under voltage protection、 Over heat protection ect.
LED Display Can display the real time running status of the inverter , monitor parameter .function parameter and fault code and other information of the inverter.
Ambient Place to be used Indoor location free from direct exposure to sun light, high humidity or dew condensation, high levels of dust, corrosive gas, explosive gas, inflammable gas, oil mist, salt and etc
Altitude Below 1000 M
Ambient Temperature -10 ℃ to +45 ℃  (Bare Machine: -10 ℃ to+50 ℃)
Humidity 20%-90% RH without dew condensation
Vibration <0.5G
Storage temperature -20~+60°C

Rated Drawings

600.jpg